Avaya Business Communications Manager 5.0 - Fault and Performance Management Manuale Utente Pagina 46

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 70
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 45
46 Telephony metrics monitoring
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
Unacceptable (desktop) The number of unacceptable errors you can
receive for a desktop phone model. The value
ranges and default thresholds are as follows:
Packet Loss Rate: The value range for this
metric is 0 to 100. The default value for
unacceptable thresholds is 5%.
Inter-arrival Jitter: The value range for this
metric is 0 to 1000. The default value for
unacceptable thresholds is 500 ms.
RTCP Round Trip Delay: The value range for
this metric is 0 to 1000. The default value for
unacceptable thresholds is 500 ms.
Warning (softclient) The number of warnings you can receive for a
softclient phone model. The value ranges and
default thresholds are as follows:
Packet Loss Rate: The value range for this
metric is 0 to 100. The default value for warning
thresholds is 1%.
Inter-arrival Jitter: The value range for this
metric is 0 to 1000. The default value for
warning thresholds is 50 ms.
RTCP Round Trip Delay: The value range for
this metric is 0 to 1000. The default value for
warning thresholds is 300 ms.
Listening R Factor: The value range for this
metric is 0 to 100. The default value for warning
thresholds is 65.
Unacceptable (softclient) The number of unacceptable errors you can
receive for a softclient phone model. The value
ranges and default thresholds are as follows:
Packet Loss Rate: The value range for this
metric is 0 to 100. The default value for
unacceptable thresholds is 5%.
Inter-arrival Jitter: The value range for this
metric is 0 to 1000. The default value for
unacceptable thresholds is 500 ms.
RTCP Round Trip Delay: The value range for
this metric is 0 to 1000. The default value for
unacceptable thresholds is 500 ms.
Variable Value
Vedere la pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 69 70

Commenti su questo manuale

Nessun commento