Avaya BRI Based Video Conferencing on BCM Technical Guida di Configurazione Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 19
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
BCM Technical Configuration Guide V1.1 May, 2006
_______________________________________________________________________________________________________________________
NORTEL External Distribution
7
MBM
Install onto appropriate BUS & Activate
Get Loop numbers
Activate Loops
ISDN
DNs
Select DNs
Assign target line
•Configure OLI
Loops
Configure as “s” interface
Assign DNs
Routing
Verify PRI pool correctly programmed
Target
Line
Map incoming spill
Polycom
Program DNs
Disable H.323 & SIP
Configure SPIDs
Figure 2: Configuration Flow
2.3 MBM
The objective of the following steps is to insert and activate the ISDN Basic Rate Interface (BRI) MBM into the
BCM.
Firstly, identify an available BUS, and set the dip switches accordingly; in this example, we are using BUS 06.
Once inserted, set the programming to “Trunk Module”.