Enabling APPN Services
2-13
Figure 2-9. SDLC Line Parameters Window
2.
Edit the Clock Source, Internal Clock Speed, Sync Line Coding, Cable
Type, and RTS Enable parameters, as follows:
Parameter: Clock Source
Default: Internal
Options: ExternalInternal
Function: Specifies the origin of the synchronous timing signals. If you set this
parameter to Internal, this router supplies the required timing signals. If
you set this parameter to External, an external network device supplies the
required timing signals.
Instructions: Set this parameter to either Internal or External, as appropriate for your
network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.13