Configuring SNMP, RMON, BOOTP, DHCP, and RARP Services
1-22 114070 Rev. A
Figure 1-11. Edit Thresholds Global Parameters Window
2.
Specify the polling interval.
Use the description that follows as a guide.
3. Click on OK to exit the window.
Parameter: Polling Interval
Default: 60 seconds
Options: 5 seconds minimum; no maximum value
Function: Sets the time interval at which the agent polls the variable to determine
whether that variable has reached the threshold.
Instructions: Specify the number of seconds for the polling interval. Remember that the
more often the agent polls the variable, the more memory it needs to
manage the thresholds for this statistic.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.6.1.2