Configuring IP Utilities
6-14
304234-A Rev 00
Using Site Manager
Complete the tasks in the following table to specify the number of minutes that
can elapse before the device disconnects the Telnet session if you fail to enter a
command.
Changing Login Retries
By changing the login retries you can determine the maximum number of login
attempts allowed before the device disconnects the Telnet session.
Using the BCC
By default, the device allows you 3 login attempts before it disconnects the Telnet
session. To change the maximum number of allowed login attempts, enter:
login-retries <
integer
>
integer
is a number from 1 to 99 login attempts.
For example, the following command line tells the device to allow 10 attempts
before it disconnects the Telnet session:
server#
login-retries 10
server#
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
Global Protocols
. The Global Protocols menu opens.
3. Choose
Telnet Server
. The Telnet Server menu opens.
4. Choose
Global
. The Telnet Server Global Parameters
window opens.
5. Set the
Command Timeout (min.)
parameter. Click on
Help
or see the
parameter description on page A-11
.
6. Click on
OK
. Site Manager saves your changes and
exits the window.