GeoTel Features User Manual VENGINE Alarms
P0602482 Ver. 04.03 Avaya Page 339
VENGINE 26028
MESSAGE
[Para <block_name >/<1>] Heap is damaged <before/after> calling
function '<function-name>' from library '<library-name>.'
SEVERITY
3
PROBABLE CAUSE
Before: Internal vengine problem.
After: The call function damaged the heap by incorrectly calling the malloc() or
free() functions.
ACTION
Before: Contact your local Avaya MPS support staff.
After: Review the function code.
Vedere la pagina 338