Using Technician Interface Scripts
2-650 117380-A Rev. A
Sample Display - show t1 line
T1 Module Line Errors:
----------------------
Yellow Red
BiPolar Alarms Carrier Alarms
Slot Conn Circuit Violtns Recvd Loss Recvd
---- ---- ------- ---------- ---------- ---------- ----------
2 1 T1-21 396177689 0 1 3
2 2 T1-22 396063622 0 4 0
2 entries in table.
BiPolar Violtns Number of bipolar violations on this line. On a T1 line, 1’s are
transmitted as alternating negative and positive pulses, and 0’s are
simply the absence of pulses. Thus a bipolar violation occurs if
there are two or more consecutive pulses of the same polarity. This
error count indicates the quality of the T1 line.
Yellow Alarms Rcvd Number of times the router has received a yellow alarm on this line.
A yellow alarm indicates that we have not lost sync, but the remote
side of the connection has detected a problem with this line.
Carrier Loss Number of instances of carrier loss detected on this line. This
typically occurs during cable removal.
Red Alarms Recvd Number of instances of out-of-frame errors detected for periods
exceeding 2.5 seconds; typically a mismatched framing format
causes this condition.