115375-A Rev. A A-1
Appendix A
Cabling Requirements for the Net Module
This appendix provides technical information about the cabling requirements for
the MCE1 net module.
MCE1 net module compliance for 120-ohm connection requires an Order No.
AA0018014 cable (F
igure A-1 and Table A-1).
Figure A-1. Cable Order No. AA0018014
Table A-1. MCE1 RJ45 to RJ45 Cable (Order No. AA0018014)
Pair Number Bay Networks Termination Remote Termination
Pin Signal Pin Signal
1 1 Receive Tip 1 Receive Tip
1 2 Receive Ring 2 Receive Ring
2 4 Transmit Tip 4 Transmit Tip
2 5 Transmit Ring 5 Transmit Ring
RJ-45 connector RJ-45 connector
Pin 8
Pin 1 Pin 1
Pin 8
10 feet
CAB0026C