Avaya E1 Manuale Utente Pagina 39

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 46
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 38
115375-A Rev. A A-1
Appendix A
Cabling Requirements for the Net Module
This appendix provides technical information about the cabling requirements for
the MCE1 net module.
MCE1 net module compliance for 120-ohm connection requires an Order No.
AA0018014 cable (F
igure A-1 and Table A-1).
Figure A-1. Cable Order No. AA0018014
Table A-1. MCE1 RJ45 to RJ45 Cable (Order No. AA0018014)
Pair Number Bay Networks Termination Remote Termination
Pin Signal Pin Signal
1 1 Receive Tip 1 Receive Tip
1 2 Receive Ring 2 Receive Ring
2 4 Transmit Tip 4 Transmit Tip
2 5 Transmit Ring 5 Transmit Ring
RJ-45 connector RJ-45 connector
Pin 8
Pin 1 Pin 1
Pin 8
10 feet
CAB0026C
Vedere la pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 45 46

Commenti su questo manuale

Nessun commento