Using Technician Interface Scripts
2-104
303560-A Rev 00
phy errors
[
circuit
<circuit name>
]
Displays loss of signal, loss of pointer, loss of frame, and out-of-cell delineation
information for the specified circuit or for all circuits. For more information on column
definitions, see the
alerts
command.
Sample Display - show atm line phy errors
ATM Module Physical Interface Errors:
-------------------------------------
Loss of Loss of Loss of Out of Cell
Slot Conn Circuit Signal Pointer Frame Delineation
---- ---- -------- ---------- ---------- ---------- -----------
4 1 A41 10 0 3 3
5 1 A51 1 0 1 1
2 entries in table.
Sample Display - show atm line phy errors circuit A51
ATM Module Physical Interface Errors:
-------------------------------------
Loss of Loss of Loss of Out of Cell
Slot Conn Circuit Signal Pointer Frame Delineation
---- ---- -------- ---------- ---------- ---------- -----------
5 1 A51 1 0 1 1
Found 1 match out of 2 entries in table.