Avaya Using Technician Interface Scripts Manuale Utente Pagina 713

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 892
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 712
303560-A Rev 00
2-665
base [circuit
<circuit name>
]
Displays the base level information for all SYNC circuits or a specific SYNC circuit. For
definitions of the columns in the table, see the
alerts
command. In addition to the states
listed under the
alerts
command, State can also be Up.
Sample Display - show sync base
SYNC Modules:
-------------
Line WAN Loc Rem Med
Slot Conn Circuit State MAC Address Number MTU Protocol Adr Adr Typ
---- ---- ------- ------ ----------------- -------- ---- -------- --- --- ---
5 1 S51 Up 00-00-A2-00-A1-73 00205101 1600 WF STND 7 7 STD
5 2 S52 Up 00-00-A2-00-A1-74 00205102 1600 WF STND 7 7 STD
2 entries in table.
disabled
Displays SYNC circuits that a user has manually disabled. For definitions of the columns
in the table, see the
alerts
command. In this case, State is Disabled.
Sample Display - show sync disabled
SYNC Modules Disabled:
----------------------
Line WAN Loc Rem Med
Slot Conn Circuit State MAC Address Number MTU Protocol Adr Adr Typ
---- ---- ------- ------- ----------------- -------- ---- -------- --- --- ---
Found 0 matches out of 4 entries in table.