Using Technician Interface Scripts
2-124
interrupt errors [circuit
<circuit name>
]
Displays interrupt errors in character reception. The BISYNC driver uses an interrupt
procedure to check for control characters in the information stream.
The table includes the following information:
Sample Display – show bisync interrupt
BISYNC Module Interrupt Errors:
------------------------------
Slot Conn Circuit BCZero BCSix BCInvalid BCErrors
---- ---- -------- ---------- ---------- ---------- ----------
1 1 S11 0 0 0 0
1 entry in table.
Slot Slot identifier
Conn Connector identifier
Circuit Name of the circuit associated with this line.
BCZero Number of error situations where no characters appear in the buffer
BCSix Number of error situations where six or more bytes of data were
received
BCInvalid Number of error situations where the fifth byte of information is
not a control character
BCErrors Total number of errors; sum of BCZero, BCSix, and BCInvalid
values