Using Technician Interface Scripts
2-628
Sample Display – show x25 alerts
X.25 Packet Level Alert Status
------------------------------
Restarts Resets Rejects Intrpts Failed VC Abnormal VC SYNC Driver
Line RX/TX RX/TX RX/TX RX/TX Connections Disconnects State
----- -------- ------ ------- ------- ----------- ----------- -----------
2.1 4 0 0 0 0 0 Up
1 Alert Entries.
base
Displays the state of the X.25 protocol in the base record. The base record controls X.25
for the entire system. State is Disabled, Down, Init (initializing), Not
Present (configured
but not yet started), or Up.
Sample Display – show x25 base
X.25 Base Record Information
----------------------------
Protocol State
-------- -----------
X.25 Up
Failed VC Connections Number of unsuccessful VC connections performed since starting
up.
Abnormal VC Disconnects Number of abnormal VC disconnections.
SYNC Driver State State of the driver: Down, Init (initializing), Not Pres (not yet
started), or Up.