Using Technician Interface Scripts
2-390
Sample Display – show lnm alerts
LNM Servers Circuit Alerts
--------------------------
Circuit LNM LNM LRM LNM LBS LNM REM LNM RPS LNM CRS
-------- -------- -------- -------- -------- -------- --------
O41 Not Pres Not Pres Not Pres Not Pres Not Pres
1 Entries found.
base
Displays the LNM Servers base record state. The base record controls LNM Servers as a
whole for the entire system. State is one of the following:
LNM REM State of Ring Error Monitor (REM). If the state is Up, the entry is
blank. Otherwise, the state is Down, Init (initializing) or Not Pres
(not present).
LNM RPS Sate of Ring Parameter Server (RPS). If the state is Up, the entry is
blank. Otherwise, the state is Down, Init (initializing) or Not Pres
(not present).
LNM CRS State of Configuration Report Server (CRS). If the state is Up, the
entry is blank. Otherwise, the state is Down, Init (initializing) or
Not Pres (not present).
Disabled User has manually disabled LNM Servers as an entity.
Down LNM Servers is not functioning.
Init LNM Servers is initializing on the system.
Not Present LNM Servers has been configured but not started.
Up LNM Servers is currently operating on the system.
Commenti su questo manuale