show sws
2-547
backup_dialing circuits
Displays primary circuits that are configured for dial backup. The display includes the
following information:
Sample Display – show sws backup_dialing circuits
Switched Services Dial Backup Circuit Information
-------------------------------------------------
Primary Backup Backup Forced Forced
Circuit Pool Mode Protocol Dial TakeDown
-------- -------- ------ --------------- -------- --------
S21 1 Master Wflt Disabled Disabled
Total of 1 Dial Backup Circuits.
Primary Circuit Circuit name of the primary circuit.
Backup Pool Identifies the backup pool available for the primary circuit; ranges
from 1 to 255.
Backup Mode Operating mode of the router, as follows:
Master – Initiates the backup call when the primary circuit fails.
SlaveWaits for the incoming call when the primary circuit fails.
Protocol Type of WAN protocol configured on this primary circuit, as
follows:
Frame Relay – Frame Relay protocol.
PPP – Point-to-Point Protocol.
Wlft – Standard protocol, a proprietary protocol used between two
Bay Networks routers. Based on the CCITT HDLC (High-level
Data Link Control) protocol, Standard provides LLC1
(connectionless, datagram) service.
Unknown – Protocol is unidentified.
Forced Dial Status of the Forced Dial parameter — Enabled or Disabled. When
Enabled, the router immediately activates the backup circuit.
Forced TakeDown Status of the Forced TakeDown parameter: Enabled or Disabled.
When Enabled, the router immediately terminates the backup
circuit.
Vedere la pagina 598
1 2 ... 594 595 596 597 598 599 600 601 602 603 604 ... 787 788

Commenti su questo manuale

Nessun commento