318 Troubleshooting your Enterprise Edge system
Enterprise Edge 2.0 Programming Operations Guide P0911588 Issue 01
Problems with module service
Check first for user problems, then wiring connections and programming errors
before replacing Enterprise Edge equipment.
1. Check that the module is properly inserted in the server or expansion cabinet.
2. Access Services, Telephony Services and then Feature settings, to ensure
that the module is not disabled. For more information, refer to the procedure,
Display the Media Bay Module status on page 279.
If the problem persists
If the AC power is present and the LED indicator on the module is off, contact your
customer service representative. If AC power is present and the LED indicator on
the Enterprise Edge system is off, replace the system power supply.
Note: Before you replace the system power supply, disconnect all central office
and station lines from the Enterprise Edge system. Power down the system
by unplugging it.
Refer to Enterprise Edge Installation and Maintenance Guide for information on
replacing components.
Refer to the following sections for more information:
• Digital Trunk Computer Module trouble on page 318
• Monitoring the T1 or PRI signal on page 320
Digital Trunk Computer Module trouble
1. Choose Resources, Media Bay Modules and the bus that the module is on to
verify that the EE-DTM is enabled and that it’s lines are provisioned. For
more information, refer to the procedure, Display the Media Bay Module
status on page 279.
Notify service provider of T1 or PRI signaling disruption.
Notify your T1 or PRI service provider before disconnecting your T1 or
PRI lines, removing power to your system, or performing any other
action that disrupts your T1 or PRI signaling. Failure to notify your T1
or PRI service provider may result in a loss of T1 or PRI service.
Commenti su questo manuale